{"id":1755,"date":"2018-01-05T22:28:52","date_gmt":"2018-01-05T20:28:52","guid":{"rendered":"http:\/\/www.inst-sim.com\/1\/?p=1755"},"modified":"2018-01-06T22:12:51","modified_gmt":"2018-01-06T20:12:51","slug":"advant-ultrasonic-flow-meter","status":"publish","type":"post","link":"https:\/\/www.inst-sim.com\/1\/mix_boks\/advant-ultrasonic-flow-meter\/","title":{"rendered":"\u0645\u0645\u064a\u0632\u0627\u062a \u0648\u0639\u064a\u0648\u0628 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 Ultrasonic Flow Meter"},"content":{"rendered":"<p style=\"text-align: center;\"><span style=\"color: #ff0000;\"><strong>\u0645\u0645\u064a\u0632\u0627\u062a \u0648\u0639\u064a\u0648\u0628 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 Ultrasonic Flow Meter<\/strong><\/span><\/p>\n<p dir=\"ltr\" style=\"text-align: center;\"><span style=\"color: #ff0000;\"><strong>Advantages and Disadvantages of an Ultrasonic Flow Meter<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-1760 size-full\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2018\/01\/Advantages-and-Disadvantages.gif\" alt=\"\" width=\"450\" height=\"320\" \/><\/p>\n<h1><strong><span style=\"color: #ff6600;\">\u0645\u0645\u064a\u0632\u0627\u062a\u00a0Advantages \u0643\u0644\u0627 \u0627\u0644\u0646\u0648\u0639\u064a\u0646 \u0644\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 Ultrasonic Flow Meter<\/span> <\/strong><\/h1>\n<table cellspacing=\"20\">\n<tbody>\n<tr>\n<td>\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">\u0641\u064a \u0643\u0644 \u0645\u0646 \u0646\u0648\u0639 \u0632\u0645\u0646 \u0648\u0635\u0648\u0644 \u0627\u0644\u0646\u0628\u0636\u0629 \u0648\u0646\u0648\u0639 \u062f\u0648\u0628\u0644\u0631 \u060c \u0641\u0625\u0646 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0636\u063a\u0637 <span style=\"color: #0000ff;\">Pressure Drop<\/span> \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646\u0647\u0645\u0627 \u0644\u0627 \u064a\u0630\u0643\u0631 .<\/li>\n<\/ul>\n<p>.<\/p>\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">\u062a\u0623\u062b\u064a\u0631 \u0644\u0632\u0648\u062c\u0629 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 <span style=\"color: #0000ff;\">Fluid Viscosity<\/span> \u0639\u0644\u0649 \u0642\u064a\u0627\u0633 \u0645\u0639\u062f\u0644 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0644\u0627 \u064a\u0643\u0627\u062f \u064a\u0630\u0643\u0631 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0643\u0644\u0627 \u0627\u0644\u0646\u0648\u0639\u064a\u0646.<\/li>\n<\/ul>\n<\/td>\n<td dir=\"ltr\">\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">The doppler and transit time ultrasonic flow meter both cause negligible pressure drop when in use for pipe flow measurement.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">.<\/p>\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">The effect of fluid viscosity on pipe flow rate measurement is negligible for both types.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*<\/p>\n<h1><span style=\"color: #ff6600;\">\u0645\u0645\u064a\u0632\u0627\u062a\u00a0Advantages \u0646\u0648\u0639 \u0632\u0645\u0646 \u0648\u0635\u0648\u0644 \u0627\u0644\u0646\u0628\u0636\u0629 Transit Time<\/span><\/h1>\n<table cellspacing=\"20\">\n<tbody>\n<tr>\n<td style=\"text-align: justify;\">\n<ul style=\"list-style-type: square;\">\n<li>\u0646\u0633\u0628\u0629 \u0627\u0644\u0625\u0632\u0627\u062d\u0629 <span style=\"color: #0000ff;\">Turndown Ratio<\/span> \u0628\u0642\u064a\u0645\u0629 20:1 \u0644\u0646\u0648\u0639 \u0632\u0645\u0646 \u0648\u0635\u0648\u0644 \u0627\u0644\u0646\u0628\u0636\u0629 <span style=\"color: #0000ff;\">Transit Time<\/span> \u0647\u064a \u0645\u0646 \u0627\u0644\u0625\u0639\u0644\u064a \u0627\u0644\u0645\u0639\u062f\u0644\u0627\u062a \u0645\u0642\u0627\u0631\u0646\u0629 \u0644\u0628\u0627\u0642\u064a \u0645\u0642\u0627\u064a\u064a\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u0648\u0627\u0633\u064a\u0631 <span style=\"color: #0000ff;\">Pipe Flow Meters<\/span> . \u0648\u0647\u0630\u0627 \u064a\u0639\u0646\u064a \u0623\u0646\u0647 \u064a\u0645\u0643\u0646 \u0644\u0644\u062c\u0647\u0627\u0632 \u0642\u064a\u0627\u0633 \u0645\u0639\u062f\u0644\u0627\u062a \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0627\u0644\u0645\u0646\u062e\u0641\u0636\u0629 \u062d\u062a\u064a 1 \u0639\u0644\u064a 20 \u0645\u0646 \u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0642\u0635\u0648\u064a \u0644\u0645\u0639\u062f\u0644 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 <span style=\"color: #0000ff;\">Maximum<\/span> <span style=\"color: #0000ff;\">Flow Rate<\/span> .<\/li>\n<\/ul>\n<ul style=\"list-style-type: square;\">\n<li>\u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0644\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 <span style=\"color: #0000ff;\">Ultrasonic Flow Meter<\/span> \u0646\u0648\u0639 \u0632\u0645\u0646 \u0648\u0635\u0648\u0644 \u0627\u0644\u0646\u0628\u0636\u0629 <span style=\"color: #0000ff;\">Transit Time<\/span> \u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0644\u0643\u0644 \u0645\u0646 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 \u0648\u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u0645\u062a\u062f\u0641\u0642\u0629 \u0639\u0628\u0631 \u0645\u0627\u0633\u0648\u0631\u0629 .<\/li>\n<\/ul>\n<\/td>\n<td dir=\"ltr\">\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">The 20:1 turndown ratio for the transit time ultrasonic flow meter is among the highest in comparison with other types of pipe flow meters. This means that an ultrasonic flow meter can accurately measure a pipe flow rate as low as 1\/20th of the maximum flow rate.<\/li>\n<\/ul>\n<p>.<\/p>\n<ul style=\"list-style-type: square;\">\n<li style=\"text-align: justify;\">A transit time ultrasonic flow meter can be used for pipe flow measurement of both liquids and gases.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>.<\/p>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-1759 size-full\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2018\/01\/Turndown-Ratio.png\" alt=\"\" width=\"483\" height=\"86\" srcset=\"https:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2018\/01\/Turndown-Ratio.png 483w, https:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2018\/01\/Turndown-Ratio-300x53.png 300w\" sizes=\"(max-width: 483px) 100vw, 483px\" \/><\/p>\n<p>*<\/p>\n<h1><span style=\"color: #ff6600;\">\u0645\u0632\u0627\u064a\u0627\u00a0Advantages \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 \u0646\u0648\u0639 \u062f\u0648\u0628\u0644\u0631 Doppler<\/span><\/h1>\n<table cellspacing=\"20\">\n<tbody>\n<tr>\n<td style=\"text-align: justify;\">\n<ul style=\"list-style-type: square;\">\n<li>\u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 \u0646\u0648\u0639 \u062f\u0648\u0628\u0644\u0631 <span style=\"color: #0000ff;\">Doppler<\/span> \u0644\u0642\u064a\u0627\u0633 \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u062f\u0641\u0642 \u062f\u0627\u062e\u0644 \u0645\u0627\u0633\u0648\u0631\u0629 \u0628\u0647\u0627 \u0633\u0648\u0627\u0626\u0644 \u0642\u0630\u0631\u0629 \u0623\u0648 \u0637\u064a\u0646 .<\/li>\n<\/ul>\n<\/td>\n<td dir=\"ltr\" style=\"text-align: justify;\">\n<ul style=\"list-style-type: square;\">\n<li>The doppler ultrasonic flow meter can be used to measure the pipe flow rate of dirty liquids and slurries.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>.<\/p>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-1758 size-full\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2018\/01\/doppler-flowmeter-ani-Low-Ar-En.gif\" alt=\"\" width=\"604\" height=\"316\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #0000ff;\">\u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u062c\u0647\u0627\u0632 \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 \u062f\u0648\u0628\u0644\u0631 Doppler \u0644\u0642\u064a\u0627\u0633 \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u062f\u0641\u0642 \u062f\u0627\u062e\u0644 \u0645\u0627\u0633\u0648\u0631\u0629 \u0628\u0647\u0627 \u0633\u0648\u0627\u0626\u0644 \u0642\u0630\u0631\u0629 \u0623\u0648 \u0637\u064a\u0646<\/span><\/p>\n<p>*<\/p>\n<h1><span style=\"color: #ff6600;\">\u0627\u0644\u0639\u064a\u0628\u00a0Disadvantage \u0627\u0644\u062e\u0627\u0635 \u0628\u0643\u0644\u0627 \u0627\u0644\u0646\u0648\u0639\u064a\u0646<\/span><\/h1>\n<table cellspacing=\"20\">\n<tbody>\n<tr>\n<td>\u064a\u0639\u064a\u0628 \u0643\u0644\u0627 \u0627\u0644\u0646\u0648\u0639\u064a\u0646 \u0627\u0644\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0639\u0627\u0644\u064a\u0629 \u0646\u0633\u0628\u064a\u0627 \u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u0627\u0644\u0623\u0646\u0648\u0627\u0639 \u0627\u0644\u0623\u062e\u0631\u064a \u0644\u0623\u062c\u0647\u0632\u0629 \u0642\u064a\u0627\u0633 \u0645\u0639 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u062f\u0627\u062e\u0644 \u0627\u0644\u0623\u0646\u0627\u0628\u064a\u0628 <span style=\"color: #0000ff;\">Pipe<\/span> <span style=\"color: #0000ff;\">Flow Meters<\/span> .<\/td>\n<td dir=\"ltr\">Both the doppler and transit time ultrasonic flow meter have a cost that is relatively high in comparison with other types of pipe flow meter.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*<\/p>\n<p><span style=\"color: #ff0000;\">\u0644\u062a\u062d\u0645\u064a\u0644<\/span> \u0627\u0644\u0645\u0642\u0627\u0644\u0629 \u0628\u0635\u064a\u063a\u0629 \u0645\u0644\u0641 <span style=\"color: #0000ff;\">PDF<\/span> \u0645\u0646 \u0647\u0646\u0640\u0627 <a href=\"http:\/\/www.inst-sim.com\/1\/mix_boks\/books00009\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-491\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2016\/09\/Book1_ani.gif\" alt=\"\" width=\"42\" height=\"42\" \/><\/a><\/p>\n<p>*<\/p>\n<table style=\"border-color: #000000;\" border=\"1\" cellspacing=\"1\">\n<tbody>\n<tr>\n<td><strong>.\u00a0 \u0627\u0644\u062a\u0627\u0644\u064a .<\/strong><\/td>\n<td><strong>. <a href=\"http:\/\/www.inst-sim.com\/1\/flow\/ultrasonic-flow-meter\/\"><span style=\"text-decoration: underline;\">1<\/span><\/a> . <\/strong><\/td>\n<td><strong>. <a href=\"http:\/\/www.inst-sim.com\/1\/mix_boks\/doppler-ultrasonic-flowmeter\/\"><span style=\"text-decoration: underline;\">2<\/span><\/a> .<\/strong><\/td>\n<td><strong>. <span style=\"color: #ff0000;\">3<\/span> .<\/strong><\/td>\n<td><strong>. <a href=\"http:\/\/www.inst-sim.com\/1\/mix_boks\/doppler-ultrasonic-flowmeter\/\"><span style=\"text-decoration: underline;\">\u0627\u0644\u0633\u0627\u0628\u0642<\/span><\/a> .<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*<\/p>\n<p style=\"text-align: center;\">\u0627\u0636\u063a\u0637 \u0647\u0646\u0627 \u0644\u062a\u062a\u0627\u0628\u0639 \u0635\u0641\u062d\u062a\u0646\u0627 \u0639\u0644\u064a \u0627\u0644\u0641\u064a\u0633 \u0628\u0648\u0643 <a href=\"https:\/\/www.facebook.com\/Instruments-Simulation-987927711244444\/\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-687\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2017\/03\/Inst-Sim-Face-ani-small.gif\" alt=\"\" width=\"284\" height=\"100\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #ff0000;\"><strong>***************************************************************<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-559\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2016\/11\/handwave-Yellow.gif\" alt=\"handwave-yellow\" width=\"125\" height=\"70\" \/><\/p>\n<h3><span style=\"color: #ff6600;\"><strong>\u0645\u0648\u0627\u0636\u064a\u0639 \u0630\u0627\u062a \u0635\u0644\u0629<\/strong><\/span><\/h3>\n<h3>\u00a0.<\/h3>\n<table cellspacing=\"20\">\n<tbody>\n<tr>\n<td><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/parshall-flume\/\"><img loading=\"lazy\" class=\"aligncenter wp-image-1376 size-full\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2017\/10\/Parshall-Flume.gif\" alt=\"\" width=\"675\" height=\"446\" \/><\/a><\/td>\n<td><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/variable-area-flow\/\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-799\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2017\/04\/Rotary-Vane.gif\" alt=\"\" width=\"200\" height=\"200\" \/><\/a><\/td>\n<\/tr>\n<tr>\n<td>\n<h3><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/parshall-flume\/\">\u0642\u0646\u0627\u0629 \u0628\u0627\u0631\u0634\u0627\u0644 Parshall Flume <\/a><\/h3>\n<h3><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/parshall-flume\/\">\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0641\u064a \u0627\u0644\u0642\u0646\u0648\u0627\u062a \u0627\u0644\u0645\u0641\u062a\u0648\u062d\u0629<\/a><\/h3>\n<\/td>\n<td>\n<h3><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/variable-area-flow\/\">\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629 \u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646<\/a><\/h3>\n<h3><a href=\"http:\/\/www.inst-sim.com\/1\/flow\/variable-area-flow\/\"> Variable Area Flowmeters<\/a><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><span style=\"color: #ff0000;\"><strong>**************************************<\/strong><\/span><\/p>\n<h3><span style=\"color: #ff0000;\"><strong>\u0645\u0644\u0627\u062d\u0638\u0629<\/strong><\/span><\/h3>\n<ul>\n<li>\u0625\u0630\u0627 \u0643\u0627\u0646 \u0644\u062f\u064a\u0643 \u0645\u0642\u0627\u0644\u0629 \u062a\u0631\u064a\u062f \u0646\u0634\u0631\u0647\u0627 \u0623\u0648 \u0644\u062f\u064a\u0643 \u062a\u0639\u062f\u064a\u0644 \u0623\u0648 \u0627\u0642\u062a\u0631\u0627\u062d \u062c\u064a\u062f \u060c \u0641\u0645\u0646 \u0641\u0636\u0644\u0643 \u0633\u062c\u0644 \u0627\u0642\u062a\u0631\u0627\u062d\u0643 \u0641\u064a \u062a\u0639\u0644\u064a\u0642 \u0639\u0644\u064a \u0627\u0644\u0645\u0648\u0636\u0648\u0639 .<\/li>\n<li>\u0623\u0648 \u0631\u0627\u0633\u0644\u0646\u0627\u00a0<img loading=\"lazy\" class=\"alignnone size-full wp-image-876\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2017\/05\/Open-message-ani.gif\" alt=\"\" width=\"28\" height=\"33\" \/> \u0639\u0644\u064a \u0627\u0644\u0628\u0631\u064a\u062f \u0627\u0644\u062a\u0627\u0644\u064a \u0644\u0646\u0634\u0631 \u0645\u0642\u0627\u0644 \u062e\u0627\u0635 \u0628\u0643 : <span style=\"color: #0000ff;\">info@inst-sim.com<\/span><\/li>\n<\/ul>\n<p><span style=\"color: #0000ff;\">\u0645\u0643\u062a\u0628\u0629 \u0645\u062d\u0627\u0643\u0627\u0629 \u0627\u0644\u0623\u062c\u0647\u0632\u0629<\/span><\/p>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-1327 size-full\" src=\"http:\/\/www.inst-sim.com\/1\/wp-content\/uploads\/2017\/10\/Wish.gif\" alt=\"\" width=\"492\" height=\"98\" \/><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0645\u0645\u064a\u0632\u0627\u062a \u0648\u0639\u064a\u0648\u0628 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 Ultrasonic Flow Meter Advantages and Disadvantages of an Ultrasonic Flow Meter \u0645\u0645\u064a\u0632\u0627\u062a\u00a0Advantages \u0643\u0644\u0627 \u0627\u0644\u0646\u0648\u0639\u064a\u0646 \u0644\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0633\u0631\u064a\u0627\u0646 \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0641\u0648\u0642 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 Ultrasonic Flow Meter \u0641\u064a \u0643\u0644 \u0645\u0646 \u0646\u0648\u0639 \u0632\u0645\u0646 \u0648\u0635\u0648\u0644 \u0627\u0644\u0646\u0628\u0636\u0629 \u0648\u0646\u0648\u0639 \u062f\u0648\u0628\u0644\u0631 \u060c \u0641\u0625\u0646 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0636\u063a\u0637 Pressure Drop \u0627\u0644\u0646\u0627\u062a\u062c \u0639\u0646\u0647\u0645\u0627 \u0644\u0627 \u064a\u0630\u0643\u0631 . . \u062a\u0623\u062b\u064a\u0631 \u0644\u0632\u0648\u062c\u0629 \u0627\u0644\u0633\u0648\u0627\u0626\u0644 Fluid Viscosity [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1760,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[15],"tags":[73,54,66,74,75],"_links":{"self":[{"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/posts\/1755"}],"collection":[{"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/comments?post=1755"}],"version-history":[{"count":7,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/posts\/1755\/revisions"}],"predecessor-version":[{"id":1776,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/posts\/1755\/revisions\/1776"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/media\/1760"}],"wp:attachment":[{"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/media?parent=1755"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/categories?post=1755"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-sim.com\/1\/wp-json\/wp\/v2\/tags?post=1755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}